Venting installation instructions, Continued – Desa (V)VC42NE Series User Manual

Page 9

Advertising
background image

9

9

www.desatech.com

116237-01D

WARNING: Do not recess vent termination into

any wall. This will cause a fire hazard.

6.

Noncombustible Exterior Wall:

Position the horizontal vent

cap in the center of the 8

1

/

2

" round hole and attach to the

exterior wall with four screws. Note: The four wood screws

provided should be replaced with appropriate fasteners for

stucco, brick, concrete or other types of sidings. Before attach-

ing the vent cap to exterior wall, run a bead of non-hardening

mastic (pliable sealant) around the outside edges to make a seal

between it and the outside wall.

Combustible Exterior Wall:

For vinyl siding, stucco or wood

exteriors, a siding standoff may be installed between the vent

cap and exterior wall. The siding standoff prevents excessive

heat from damaging the siding materials. Siding material

must be cut to accommodate standoff. Bolt the vent cap to the

standoff. Apply non-hardening mastic around outside edge of

standoff. Position the standoff/cap assembly in the center of

the 10

3

/

4

" square hole and attach to exterior wall with wood

screws provided (see Figure 11). The siding standoff must sit

flush against the exterior fascia material.

7.

Combustible Exterior Wall Only:

Slide the wall firestop over

the vent pipe before connecting horizontal run to vent cap (see

Figure 12).

8. Carefully move fireplace, with vent assembly attached, toward

wall and insert vent pipe into horizontal termination. The pipe

overlap should be a minimum of 1

1

/

4

" (see Figure 13, page 10).

9.

Combustible Exterior Wall Only:

Slide wall firestop against

interior wall surface and attach with screws provided (see

Figure 12). See Figure 13, page 10 for horizontal termination

details.

VENTING INSTALLATION

INSTRUCTIONS

Continued

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

Figure 10 - Installing Horizontal Vent Cap (Noncombustible

Exterior)

Figure 11 - Installing Siding Standoff (Combustible Exterior)

Vent Cap

(Horizontal

Termination)

Interior Wall

Surface

Wall

Firestop

Horizontal

Vent Pipe

Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe

Screw

Wood Screw

Vent Cap

Cut Siding Away

to Fit Standoff

Wood Screw

Screws

Standoff

Vent Cap

Apply Mastic

to All Four Sides

Advertising
This manual is related to the following products: