8

5.2

Of the metering body

The following faults may be appear:



Magnetic coupling deterioration,



Deterioration of the torsion or reading spring,



Wearing out of torsion shaft bearings,



Wearing out or deterioration of the lever and target disk.

If any of these breakdowns occurs, it is preferable to repair it in TECFLUID S.A.
workshops, as a new calibration will be normally necessary.

6 CLEANING

In line

Pass the normal cleaning agent through the installation.

In the workshop

It should be done with soft brushes. Never use sharp objects or metal brushes.

7 TECHNICAL

CHARACTERISTICS

Accuracy:

DP65: ± 2.5% full scale

DP500: ± 4% full scale

Rangeability: 10:1

Scale length: ~100

mm.

Scales: Direct according to fluid to be measured or in %.

Operation:

Vertical with upwards flow (BD)

Vertical with downwards flow (DAB)

Horizontal with right to left flow (DES)

Horizontal with left to right flow (ED)

Connections: DP65 Between flanges.

DP500 EN 1092-1, ANSI, JIS flanges.

Other flange standards on request.

Materials:

Body: Plastic coated steel, EN 1.4404 (AISI 316L)

Indicator housing: IP65 in coated aluminium (standard)

EN 1.4404, PP, others on demand

Working

pressure:

PN40 DN40

DN80

PN16 DN100

DN300

PN10 DN250 … DN500 (DP500)

Other pressure ratings available on request.

Process temperature:

- Body in plastic coated steel: -20ºC … +130ºC.

- Body in EN 1.4404 (AISI 316L), PTFE bearings: -20ºC … +150ºC.

- Body in EN 1.4404 (AISI 316L): bronze bearings: -20ºC … +300ºC.