Tecfluid DP Series User Manual

Page 9

Advertising
background image

9

Mounting length:

DP65:

65 mm

DN40 … DN300

DP500:

500 mm

DN250 … DN300

600 mm

DN350 … DN400

700

mm

DN500

Optional limit switches in the indicator housing:

DP-AMM

1 or 2 micro-switches with potential free contacts

Maximum current:

3A

Máximum voltage:

250 VAC

DP-AMD

1 or 2 slot inductive sensors, acording to EN60947–5-6 (NAMUR)

Power supply: 8.2 VDC

Optional transmitters:

TH5

Position transducer, with analog output. 2-wire connection.

Power supply: 12 ... 36 VDC
Output signal: 4-20 mA

TH5T

Position transducer, with totalizer and analog output. 2-wire connection.

Power supply: 12 ... 36 VDC
Output signal: 4-20 mA

TH5H

Position transducer, with analog output. 2-wire connection.

Power supply: 18 ... 36 VDC
Output signal: 4-20 mA
HART protocol

TH5TH

Position transducer, with totalizer and analog output. 2-wire connection

Power supply: 18 ... 36 VDC
Output signal: 4-20 mA
HART protocol

Conforms with the Pressure Equipment Directive 97/23/EC
This equipment is considered as being a pressure accessory and NOT a safety accessory
as defined in the 97/23/CE directive, Article 1, paragraph 2.1.3.

Conforms with Directive 2006/95/EC (Low Voltage)

Conforms with Directive 2004/108/EC (Electromagnetic compatibility)
Conforms with Directive 2002/96/EC (Waste electrical and electronic equipment)

All the limit switches and transmitters can be optionally supplied for use in potentially
explosive atmospheres.
ATEX certification

II 1 GD

Ex ia IIC T4 or T6