Technical Data

Mounting: Vertical.

Connection: DN-40 PN-16 DIN 2501 Flange.

R 1½” BSP thead.
(Others available on request).

Maximum length: AISI-316 ... 6000 mm.

PVC, PTFE ... 2500 mm.
PVC, PTFE ... 6000 mm
(internal AISI-316).

Precision: ± 2 mm.

Hysteresis: ± 4 mm.

Working pressure:

PN-16 AISI-316.
PVC, PTFE with internal AISI-316 tube.
PN-10 PVC, PTFE.

Liquid temperature:

-20ºC...+150ºC en AISI-316, PTFE.

0ºC...+50ºC PVC.

Ambient temperature:

-20ºC...+60ºC AISI-316, PTFE.
0ºC...+50ºC PVC.

Liquid density: From 0,45 to 3 kg/l.

Liquid viscosity: Maximum 1500 cSt.

Contacts: Reed 1 A 220 V.

(maximum 9 with minimum separation

of 20 mm)

Conforms with Directive 73 / 23 / CEE

2

No.

Piece

Materials

LC-.../INOX

LC-.../PVC

LC-.../PTFE

1

Enclosure

DIN 43650/

Aluminium

DIN 43650/

Aluminium

DIN 43650/

Aluminium

2

Connection

AISI-316

PVC

PTFE

3

Rod

AISI-316

PVC

PTFE

4

Float

AISI-316

PVC

PTFE

5

Magnet

Alnico

Alnico

Alnico

6

Reed switch

-

-

-

7

Float stop

AISI-316

PVC

PTFE

CONSTRUCTION

OPERATION

Inside the guide tube, reed switches are mounted at the
alarm/control points..
As the float passes the position where a reed switch is
located, the magnetic field from the float actives the switch.
The maximum number of alarm or control points is 9.

Advertising