104131

OWNER’S MANUAL

PRODUCT
IDENTIFICATION

NATURAL GAS
SUPPLY

The user must furnish the natural gas supply
and the connections to the heater.

Regulate the natural gas supply down from
a minimum 6 inches water column to a
maximum of 1/2 psi. The natural gas supply
capacity should be able to supply a mini-
mum of 100 cubic feet of gas at pressure for
each heater connected to the system.

Consult your natural gas supplier for proper
sizing of the natural gas supply lines.

Follow all local ordinances and codes. In the
absence of local ordinances and codes, refer
to the National Fuel Gas Code Handbook,
NFPA54/ANSI Z223.1 and the Natural gas
Installation Code, CAN/CGA B149.2.

VENTILATION

WARNING: Provide at least a

3 square foot opening of fresh,
outside air while running heater.
If proper fresh, outside air venti-
lation is not provided, carbon
monoxide poisoning can occur.
Provide proper fresh, outside air
ventilation before running heater.

FRESH OUTSIDE AIR OPENING
REQUIREMENTS

HEATER

SQUARE FOOT

SIZE

OPENING

100,000 Btu/Hr

3.0

SPECIFICATIONS

Rating (Btu/Hr)

100,000

Fuel

Natural Gas Only

Fuel Consumption

Cubic Feet/Hour

97

Supply Pressure (To Regulator)

Maximum

1/2 psi

Minimum

6" w.c.

Manifold Pressure

4" w.c.

Weight (Pounds)

23

Shipping Weight (Pounds)

27

Size - L x W x H (Inches) 16 x 16 x 29.5

Figure 1 - Product Identification

INSTALLATION

1.

Provide natural gas supply system.

2.

Install plumbing to a low pressure natu-
ral gas source. The source must be regu-
lated to 1/2 psi maximum. The plumb-
ing must be a minimum 3/4 inch i.d.
hose or flexible connector not over 10
feet long.

WARNING: Test all gas pip-

ing and connections for leaks
after installation or servicing.
Never use an open flame to check
for a leak. Apply a mixture of
liquid soap and water to all joints.
Bubbles forming show a leak.
Correct all leaks at once.

WARNING: Review and un-

derstand the warnings in the
Safety Information Section, page
2. They are needed to safely op-
erate this heater. Follow all local
codes when using this heater.

Figure 2 - Hose and Valve Inlet

Hose

Valve
Inlet

Ignitor Electode

Pilot Burner

Piezo Ignitor Button

Regulator

Automatic
Control Valve
Button

Base

Shell

Main Burner Tube

Nozzle

Top

Emitter

Valve Inlet

Thermocouple

Continued