Troubleshooting – Desa GMP16 User Manual

Page 22

Advertising
background image

www.desatech.com

113048-01C

22

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

Yellow flame during burner com-
bustion

Slight smoke or odor during ini-
tial operation

Heater produces a whistling noise
when burner is lit

White powder residue forming
within burner box or on adjacent
walls or furniture

POSSIBLE CAUSE

1. Not enough air

2. Gas regulator defective
3. Clogged or dirty burner

1. Residues from manufactur-

ing processes

1. Turning control knob to HI

or to position 5 when burner
is cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice

1. When heated, vapors from

furniture polish, wax, carpet
cleaners, etc. may turn into
white powder residue

REMEDY

1. Check burner for dirt and de-

bris. If found, clean burner
(see Cleaning and Mainte-
nance
, page 19)

2. Replace gas regulator
3. Clean burner (see Cleaning

and Maintenance, page 19)

1. Problem will stop after a few

hours of operation

1. Turn control knob to LO or

position 1 and let warm up for
a minute

2. Operate burner until air is re-

moved from line. Have gas
line checked by local propane/
LP gas company

3. Observe minimum installation

clearances (see Figure 4, page 8)

4. Clean burner (see Cleaning

and Maintenance, page 19) or
replace burner orifice

1. Turn heater off when using

furniture polish, wax, carpet
cleaners, or similar products

Advertising
This manual is related to the following products: