Dynacord Professional Power Amplifiers User Manual

Page 32

Advertising
background image

32

Cl s

eries

front panel

The dB-calibrated level controls are implemented as

ultra-precise detent potentiometers that are recessed

in the front panel to protect them from accidental

contact. Power, Protect, Signal and Limit LEDs provide

a quick overview of the operating status.

rear panel

The electronically balanced XLR IN / OUT sockets

are provided for direct operation with professional

mixing consoles and signal processors. All the models

in the CL series are designed for a Constant Gain of

32 dB.

The power outputs for Channels A and B are on

Speakon connectors. The signal of Output B is ad-

ditionally available on pins ±2 of Output A, so that

with 4-pin wiring a two-way system can be driven.

A Ground Lift switch is also provided to separate the

chassis ground from the signal ground in order to

eliminate ground loop hum.

safetY circuits

The complete CL series is equipped with protections

against overheating, overloading, short-circuits, DC

and HF as well as a Back-EMF protection. With the

Soft Start system, the power outputs are switched

on via a relay when a safe operational state has been

reached and a power-up delay prevents the mains

fuses being activated.

German engineering. Manufactured in accordance

with the Bosch Production System (BPS) in Straubing,

Germany.