Rear panel, Building networks for people, Com port – D-Link DVS-301 User Manual

Page 8: General i/o terminal block

Advertising
background image

Building Networks for People

DVS-301 User Manual v1.00

2

Rear Panel

Ethernet 10/100 socket

Connect to Ethernet network with a UTP category 5 cable that cannot exceed 100 meters. Once

the Ethernet cable is connected without error, Video Server will utilize Ethernet interface

regardless of modem connection.

COM port

This RS232 serial port can connect with a modem or included null modem cable to utilize

dial-up network when Ethernet is not available. If Video Server operates with Ethernet interface,

administrators may use this port to control PTZ camera attached to VIDEO.

General I/O terminal block

1

Å DI+ INPUT

(Max. 50mA, 12VDC)

2

Å DI-

INPUT

3

Å SW_COMMON OUTPUT

(short with NC at initial state)

4

Å SW_NOPEN

OUTPUT

(Max. 1A, 24VDC or 0.5A, 125VAC)

5

Å RS485 B

(inverting)

6

Å RS485 A

(non-inverting)

Advertising