Tri Tool 757RSS Hydraulic Power Supply User Manual

Page 13

Advertising
background image

13

Model 757RSS, Hydraulic Power Supply

92-0565 : Rev. 070912

WARNING:

Verify that the slide lock sleeves on the quick disconnects are fully engaged.

CONNECT THE HYDRAULIC HOSES TO THE UNIT

The quick disconnects on the hydraulic supply are pre-installed to match the forward
flow line on all TRI TOOL Inc. equipment with the female hose quick disconnect
being the forward or high pressure line.

Connect the hoses to the machine to be used.

Check the level of hydraulic fluid in the reservoir.

There is a minimum of 11 gallons (41 liters) required.

An additional 1.6 gallons (6 lt.) of fluid is required for every 100’ (50 ‘ [12.7 m] hose
set) of 5/8” (16 mm) diameter hose connected to the power supply.

CONNECT THE UNIT TO A POWER SOURCE.

Check the motor rotation if any main power re-connections have been made since
the initial set-up checks.

The unit is wired to match the source power.

Push down on the START Button to start the unit.

Operator's Pendant

The Hydraulic Pump will be damaged if it is driven backwards.

The charge pump doesn’t circulate oil if rotated in the reverse direction and therefore
overheats in about 10 seconds of continuous reverse running.

Advertising