Triplett 9055 User Manual
Page 39

37
Battery and Fuse Replacement
If “ “ appears on the LCD display, replace the battery.
Remove 8 screws on the back cover and open the case.
Replace the exhausted battery. Reassemble case.
Fuses usually blow because of operator error. If a fuse blows,
examine the test setup and correct any problems before
replacing the fuse(s) and retesting. Open the case by
removing 8 screws. Replace the fuses only with fuses of
equal rating. Using inappropriate fuses may damage the
meter or result in user injury.
Warning:
Never open the case of the meter with the test leads
connected to the meter. Doing so may result in user injury.
Replacement Parts:
Test Leads ………………………………………... 79-808
Fuse 1: 10A / 600V fast blow, 1-1/4” x ¼” …….. 3207-132
Fuse 2: 500mA / 660V fast blow, 5 x 20mm ….. 3207-136