Slide number 5, Cat acert installation – TS Performance 8210202 User Manual

Page 5

Advertising
background image

Troubleshooting

7

4

Insulation: Module

CAT ACERT Installation

1.

Shut machine off

2.

Locate the factory injector harness connections on the

driver’s side of the engine (labeled A and B in the picture

above).

3.

Disconnect the factory harness from the connectors.

4.

Connect the supplied MP-HD harness into the appropriate

connections. Our harness is labeled (A) and (B). (A) will

connect to the factory connection toward the front and (B)

will connect to the conection to the rear. (On our harness,

connector A will be in the middle of the harness and (B) will

be at the end of the harness.

5.

Now connect the factory harness to the remaining open

connections on the MP-HD harness.

Troubleshooting Section

1. Be sure you have nice clean +12 Volt power to

RED

wire with eyelet on fuel module.

2. The BLACK wires on the module should be

routed to a good clean chassis ground.

3. Check all wiring connections, and confirm that

they are secure.

4. If engine is still performing poorly, or any other

problems exist in engine performance,

UNPLUG the MPHD Module while leaving the

module harness still connected to the injectors

in the valve cover. Start the engine and

examine engine performance once again.

**If engine still performs poorly, confirm that

all wiring connections are secure and contact

TS Performance at (270) 746 – 9999.**

Advertising