Verilink 300 (CG) Configuration/Installation Guide User Manual

300 esf csu/dsu, Productivity series 300, Configuration guide

Advertising
background image

SD

RD

FRAME

ERROR

YELLOW

TEST

NORM

RL

LL

CSU/DSU

PRODUCTIVITY

SERIES

300

T

R

A

N

S

P

O

R

T

®

300 ESF CSU/DSU

Configuration Guide

Part Number 45-00044

Rev 2.0

7

6

5

4

3

2

1

1

Send Data: This green LED lights when the SD data lead is a mark and is off when the lead is a space.
Therefore, the LED will vary from full intensity to off depending on the relative number of marks and spaces.

2

Receive Data: This green LED lights when the RD data lead is a mark and is off when the lead is a space.
Therefore, the LED will vary from full intensity to off depending on the relative number of marks and spaces.

3

Frame: This green LED lights when the unit is in frame synchronization with the T1 line.

4

Error: This red LED lights if the internal alarm circuitry detects any of the following conditions from the incoming T1 signal:
BPVs, FBEs, CRCs, loss of signal/loss of sync, or more than 175 zeros.

5

Yellow: This red LED lights if the internal alarm circuitry detects a remote (yellow) alarm signal from the far end terminal equipment.
This occurs if the far end terminal is out of sync with the T1 signal from the network.

6

Test: This amber LED remains lit if the unit is in a test mode, either by manually depressing the loop switch or by receipt of a test
command from the facility.

7

Test Switch: This 3-position switch is used as follows: Depressing the switch to the ‘LL’ position places the unit in a local loop
mode. Data from the DTE is looped back to the DTE and is also transmitted to the network (the data from the network is open).
Depressing the switch to the ‘RL’ position initiates an automated V.54 remote loop and BERT sequence of assigned data channels. The
‘TEST’ LED will be green if the test is successful (the far end unit loops and returns the data error free with the V.54 code). If errors
are detected, the ‘TEST’ LED will be red.

Front Panel Description

TxPORT 300 Front Panel

T

R

A

N

S

P

O

R

T

®

SPECIFICATIONS

Network Interface

Line Rate:

1.544 Mbps (± 50 bps)

Line Framing:

D4 or ESF

Line Code:

AMI or B8ZS

Line Impedance:

balanced 100

(± 5%)

Input Signal:

DS1, +1 to -27 dB (ALBO)

Output Signal:

3.0 V (±15%) base-peak into
100

Line Build Out:

0, -7.5, -15, and -22.5 dB atten-
uation

Line Protection:

1000 V lightning, input/output

Jitter Control:

per TR62411 and T1.403

Pulse Density:

per TR62411

V.35 Interface

Data Rate:

Synch, N x 56 or N x 64 kbps

Clocking:

Internal or external

Industry Standards

FCC:

Part 15 Subpart B, Class A

UL:

1459 2

nd

Edition

CSA:

C22.2 No. 225-M90

IC:

CSO3 Issue 8

ANSI T1.403: 1989

TR 54016:

September 1989

TR54019:

April 1988

TR 62411:

December 1990

Power

AC Power:

115 VAC (± 10%), 150 mA max,
20 Watts, 73 BTU max.

Connection: 5-foot

power

cord

Mechanical

Mounting:

Desktop, wall, or vertical rack

Dimensions:

1.75 inches (4.45 cm) high

6.8 inches (17.27 cm) wide

10.5 inches (26.67 cm) deep

2 pounds (0.91 kg)

Environmental

Operating Temp:

32° to 122°F (0° to 50° C)

Storage Temp:

- 4° to 185°F (- 20° to 85° C)

Humidity:

95% max (non- condensing)