Loops – Verilink 310 (CG) (CG) Configuration/Installation Guide User Manual

Page 2

Advertising
background image

T

R

A

N

S

P

O

R

T

®

7

6

5

4

3

2

1

9

7

6

5

4

3

2

8

S1

S2

V.35

1

93-130

VAC

1 - 5 DSOs Assigned: These five positions select the bit rate and the number of DSOs assigned to the

channel (refer to the table below).

6

Rate Multiplier: Sets the multiplier for the input timing (refer to the table below). The unit oper-
ates at any data rate that is a multiple of 56 or 64 kbps.

7

Channel Assignment: The Contiguous mode assigns the channels as a block beginning at DS0
channel 1. If ‘Alternate’ is selected, channel assignments are made with an idle channel following
each data channel.

8

Control Lines: ‘On’ permanently sets the CTS, DSR, and CD leads to ON. With ‘Follow’, the
DSR lead follows T1 sync, the CTS lead follows RTS, and the CD lead follows the density status
of the incoming T1 signal (

175 zeros = CD OFF). The TM line goes high when the unit is in a

local or remote test mode.

9

Data Invert: Determines whether the data bits are inverted.

NOTE: The ‘A’ position is the factory default for
all switch settings. If a particular user configuration
requires that a switch be placed in the ‘B’ direction,
then mark this sheet for future reference.

Circuit Pin #

Signal Name

DCE

101

A

Frame Ground

Ground

102

B

Signal Ground

Ground

103

P/S

Transmit Data

In

104

R /T

Receive Data

Out

105

C

Request To Send

In

106

D

Clear To Send

Out

107

E

Data Set Ready

Out

109

F

Data Carrier Detect

Out

113

U /W

External Transmit Clock

In

114

Y/AA

Transmit Clock

Out

115

V/X

Receive Clock

Out

142

K

Test Mode

Out

V.35 Interface

DSO S1 - 1 S1 - 2 S1 - 3 S1 - 4 S1 - 5 S1 - 6 (A) S1 -6 (B)

1

B B B B B 56

kb 64

kb

2

B A B B B 112

128

3

A A B B B 168

192

4

B B A B B 224

256

5

A B A B B 280

320

6

B A A B B 336

384

7

A A A B B 392

448

8

B B B A B 448

512

9

A B B A B 504

576

10

B A B A B 560

640

11

A A B A B 616

704

12

B B A A B 672

768

13

A B A A B 728

832

14

B A A A B 784

896

15

A A A A B 840

960

16

B B B B A 896

1024

17

A B B B A 952

1088

18

B A B B A 1008

1152

19

A A B B A 1064

1216

20

B B A B A 1120

1280

21

A B A B A 1176

1344

22

B A A B A 1232

1408

23

A A A B A 1288

1472

24

A A A A A 1344

1536

DTE

NET

Local Loopback

DTE

NET

Remote Channel Loop (V.54)

DTE

NET

* Signal regeneration only

*

CSU Line Loop (Inband or LLB)

Loops

1

Data In (R1)

2

Data In (T1)

3 /6

Not Used

4

Data Out (R)

5

Data Out (T)

7 /8

Chassis Gnd

Network Pinout

1 - 2 Timing Source: This position selects the source of unit clocking (refer to the Switch S2 table).

3

Not used.

4

Network Framing: This position selects the network framing to either ESF or D4.

5

Network Coding: This position selects the network line code format to either AMI or B8ZS.

6 - 7 Network LBO: This position selects the network LBO (line build out) signal level of the data

transmitted towards the T1 facility (refer to the Switch S2 table).

Switch S1 Description

Switch S2 Description

6

5

4

3

1

7

9

8

2

56 k

bps

C

o

ntiguou

s

C

o

ntrol

D

at

a In

v

ert

64

kbps

Al

ter

n

ate

Contr

o

l

Dat

a I

n

v

er

t

F

o

llo

w

On

No

Ye

s

Switch S1

DSOs Assigned

(see table at bottom)

8

1

NET

A

B

A

B

127 Jetplex Circle

Madison, Alabama 35758

Sales and Marketing

800-926-0085

205-772-3770

[email protected]

RMA/ Returns

800- 926-0085, ext. 2282

Technical Support

800-285-2755
205-772-3770

[email protected]

Not

ES

F

AM

I

No

t

D4

B8Z

S

5

4

3

2

1

6

7

B

A

A

A

B

A

Network clock (looped)

Internal clock (master)
CPE clock (external)

Timing

Source

Network

LBO

B

B

B

A

A

A

B

A

0

-22.5

-7.5

-15

Switch S2

A

B

Us

ed

Us

ed

B B Not Valid

Advertising