Verilink 4019-1 (WS) Configuration/Installation Guide User Manual
Verilink Computer hardware

880-501286-001-C
April 1994
Page 1 of 1
WT-1 JUMPER
DTE Receive Distance
SELECT DESIRED OPTION:
1 - 2*
0’ - 85’ *
3 - 4
85’ - 375’
5 - 6
375’ - 655’
WT-2 JUMPER
DTE Transmit Distance
SELECT DESIRED OPTION:
1 - 2 *
0’ - 85’ *
3 - 4
85’ - 375’
5 - 6
375’ - 655’
S2
Transmit (Artificial Line)
SELECT DESIRED OPTION:
15dB
0 - 1000 ‘ twisted copper
7.5dB *
1000’ - 2000’ twisted copper *
0dB
2000’ - 3000’ twisted copper or local
DS3 mux, radio, or other equipment
requiring DSX level
S1
Critical Circuitry Power
SELECT DESIRED OPTION:
SP *
Span power *
WL
Local Power Wet Loop
(CSU applies sealing current)
DL
Local Power Dry Loop
(Loop any sealing current)
NOTES:
1. * = These are the factory defaults and are those most commonly used in the field.
2. For additional installation information, refer to manual Part No. 880-500497-001.
3. FCC Reg: GIC472-16545-DE-N
FIC: O4DU9-B
4. Telco jack: DA-15 or wire-wrap
...
...
... ...
5
1
6
2
WT1
5
1
6
2
WT2
DL WL SP
S1
0 7.5 15
S2
REGENERATOR
4019-1 CSU Plug-In
Installation Worksheet
D