Verilink PRISM 3021 (CG) Configuration/Installation Guide User Manual

Configuration guide, Front panel description, Specifications

Advertising
background image

Front Panel Description

Index

Item

Function

1

STATUS

If neither LED is On, the 3021 is not powered. If only the green LED is On, the 3021 is powered and may be functioning normally. If only the red LED is On, there
is a fault that exceeds alarm thresholds or another type of 3021 failure.

2

TD

This green LED is On during a mark condition on the high-speed transmit data line.

3

RD

This green LED is On during a mark condition on the high-speed receive data line.

4

RTS

This green LED is On when the request-to-send signal is active.

5

DTR

This green LED is On when the data-terminal-ready signal is active.

6

FAR/LOC
Switch

This switch is used for local testing and setting the SUPV port rate when downloading firmware for the Flash PROM. For testing, setting the switch to LOC performs a network
LLB and setting the switch to FAR sends five seconds of in-band loop code and then sends the BERT pattern selected in the user interface. The default pattern is QRSS.

7

Activity
Indicators

These two small, recessed LEDs indicate supervisory/network manager port activity.

8

SUPV Port

The supervisory jack provides direct terminal access to control and monitor the 3021.

9

BV/CR/FE

This LED is On when the unit detects bipolar violations, cyclic redundancy checking errors, or framing errors.

10

LOS/OOF

This LED flashes when the unit detects a loss-of-signal condition or remains On during an out-of-frame condition.

11

AIS

This LED is On when the network interface is receiving an alarm indication signal.

12

REM ALM

This LED is On when the network interface is receiving a remote alarm indication.

13

LOOP

This LED is On when the network interface is in a line loopback.

14

TST

This LED is On when a BERT is in progress.

15

ERR

This LED is On when BERT pattern errors are detected.

T

R

A

N

S

P

O

R

T

®

3021 E1 NTU/DSU

Configuration Guide

45-00112

1.0

Specifications

Network Interface

Service Types:

CEPT/E1

Line Rate:

2.048 Mbps (

±

50 ppm)

Framing:

CAS or CCS

Line Code:

AMI or HDB3

Input Signal:

0 to -22.5 dB ALBO

Line Connection:

75

:

BNC

120

: DB-15

,

twinax,

and RJ- 48

Output Signal:

Per G.703 with 75-

or

120-

option

Surge Protection:

1000 volts

High-Speed Data
Port Compatibility: ITU V.35 female

DB-25, female 34-pin
through adapter cable,
ITU X.21 female
DB-15; EIA-530 DB-25

Rate:

Synchronous, N

×

56, or

N

×

64 kbps (N = 1 to 31)

Clocking:

Internal or external

Data Invert:

Enabled or disabled

Configuration

Configuration:

Card-edge switches

Terminal interface on the
supervisory port, Telnet
session using the 8100A
SNMP Management
System. Soft configura-
tion is non-volatile.

Diagnostics

Performance:

RFC1406 (with the 8100A)

Status:

Front panel LEDs for
network, testing, and DTE

Network Loopbacks: Line, payload,

and proprietary

E1-DTE Loopbacks: Line and proprietary

DTE Loopbacks:

Responds to V.54 in-band
loop codes and performs
bidirectional fractional-
port loopback

Power

Power:

- 48 VDC, 150 mA, max;
7.2 W, (24.6 BTU, max)

Mechanical

Mounting:

Wall, vertical, horizontal
rack, TxPORT 1051
chassis, or standalone

Weight:

1 pound, nominal

Compliance

FCC Compliance:

Part 15, Class A, Subpart B

US Safety:

UL 1950, 3rd Ed. (Pending)

Canadian Safety:

CSA: C22.2 No. 950- 95
(Pending)

G.703:

Signal Waveform

G.704:

Framing

G.732:

Multiframing

G.823:

Jitter

G.831:

Framing Requirement

Environmental

Operating Temp:

0

°

to 50

°

C (32

°

to 122

°

F)

Storage Temp:

-20

°

to 85

°

C (-4

°

to 185

°

F)

Relative Humidity:

95% max., non-condensing

LO

C

FA

R

D T E

TD

RD

RT

S

DT

R

ST

A

T

US

TRANSPORT

®

E1 CSU/DS

U

N E T

BV/CR/

F

E

L

O

S

/OOF

AIS

REM

AL

M

LO

O

P

TS

T

ERR

2

3

4

11

12

5

6

7

8

9

10

1

13

14

15

S

U

P

V

1

8

3021

T S T

SUPV Port

Pin

SUPV Port

Interface

1

Control Out

2

Signal Ground

3

Data Out

4

Data In

5

Signal Ground

6

Control In

Advertising