Verilink PRISM 3111 (CG) Configuration/Installation Guide User Manual

Configuration guide, Specifications

Advertising
background image

Specifications

Network Interface

Line Rate:

1.544 Mbps (

±

50 ppm)

Line Framing:

D4 or ESF

Line Code:

AMI or B8ZS

Input Signal:

0 to

27 dB ALBO

Connection:

RJ-48C jack, 100

(

±

5%)

Output Signal:

3.0 V (

±

10%) base –peak into

100

with protection

Line Build Out: 0,

7.5,

15,

22.5 dB

attenuation

Transient Voltage: 1000 V protection, fused

in/ out

Jitter Control:

per TR 62411 and T1.403

Timing Source:

Internal, recovered line clock,
external DTE, T1 DTE

Ones Density:

B8ZS, Nx56 bit stuffing,
alternate fill; TR 62411

Equipment Interface

DTE Ports:

3111 single and 3112 dual

Compatibility:

ITU V.35, female 34-pin
EIA-530, female 25-pin

Data Rate:

Synchronous, Nx56 kbps or
Nx64 kbps (where N = 1 to
24); independent selection on
each port

Clocking:

Internal, External,
Oversample

Data Invert:

Independent selection on
each port

Supervisory Port

Connection:

8- pin modular (RS-232)

Data Rates:

1.2, 2.4, 9.6, and 19.2 kbps

SLIP Port

Connection:

8- pin modular (RS-232)

Data Rates:

1.2, 2.4, 9.6, and 19.2 kbps

Ethernet (option)

Connection:

8- pin modular (RJ-45)

Network Protocol: TCP/IP-based networks

Data Rate:

10 Mbps

Compatibility:

10BASE- T

Token Ring (option)

Connection:

8- pin modular (RJ-45)

Network Protocol: TCP/IP-based networks

Data Rate:

4 or 16 Mbps

Compatibility:

Type 3 unshielded twisted
pair

T1 DTE (option)

Line Rate:

1.544 Mbps, ± 50 ppm

Line Framing:

D4 or ESF

Line Code:

AMI or B8ZS

Input Signal:

DSX1 to

6 dB

Connection:

RJ-48C modular jack
(100

Ω,

± 5%)

Output Signal:

Selectable DSX1 level from 0
to 655 feet in six increments

Dial Backup

Connection:

RS-232, 10-pin modular

Backup Service: PSTN external device

Configuration:

Information for backup unit
is stored in unit and
transmitted to backup unit by
in-band AT commands

Dialing:

Numbers programmed and
stored in unit and transmitted
to backup unit by in-band AT
commands or DTR dialing
(assertion)

Restoral:

Manual or automatic restoral
to leased line service

Diagnostics

Performance:

Monitoring per TR 54016
and T1.403

Network Loops: Line, payload, or

maintenance loopback

Fractional Loop: Generates and responds to

in-band V.54 loop

DTE Port Loops: Bidirectional loop toward

DTE and network

T1 DTE Loops: MLB and LLB toward DTE

BERT:

Multiple test patterns toward
network or DTE ports

Alarms

Activation:

Programmable thresholds

Reporting:

Front panel LEDs, call out on
alarm (COA), SNMP traps

Power

115 VAC:

120 mA, 7 W max,
24 BTU max

48 VDC:

180 mA, 9 W max,
31 BTU max

Mechanical

Mounting:

Desktop or horizontal rack

Dimensions:

11.75" (29.8 cm) wide

1.75" (4.45 cm) high

9.5" (24.1 cm) deep

Weight:

3 pounds (1.36 kg)

Environmental

Storage Temp:

32

°

to 122

°

F (0

°

to 50

°

C)

Operating Temp:

4

°

to 185

°

F (

20

°

to 85

°

C)

Humidity:

95% maximum
(non-condensing)

TEST

LOOP

BACKUP

NET

TEST ALARM POWER

PRISM 3111

T

R

A

N

S

P

O

R

T

®

SCROLL

EXIT

SELECT

BACKUP TEST ALARM POWER

PRISM 3111

T

R

A

N

S

P

O

R

T

®

45-00103

6.0

PRISM 3111/3112

Configuration Guide

PRISM 3111 with LCD Option

PRISM 3111

Button or
Indicator

Unit

Description

TEST

Non-LCD Press once to transmit five seconds of in-band loop code network. If S2-8 is set to Clear Loop, the unit goes into test mode and

does not generate an alarm. If S2-8 is set to BERT, the last test pattern selected in the terminal interface is transmitted toward
the network.

LOOP

Non-LCD Press once to activate a line loopback. Press again, to clear the loop and turn off the LOOP indicator.

EXIT

LCD

The EXIT button allows exiting a current menu option which then places the unit in the next higher menu level. If the unit is at
the main menu, pressing EXIT logs off the unit.

SCROLL LCD

The SCROLL button allows reviewing the options or selections for a menu level.

SELECT LCD

The SELECT button allows choosing the option or value for a field.

NET

Non-LCD This indicator is green when the unit is in frame sync; amber when receiving a yellow alarm from the far end; and red when out

of sync and/or has lost signal.

BACKUP Both

This amber indicator flashes when dialling, connecting, or disconnecting. This indicator is on continuously when active.

TEST

Both

This indicator flashes green when the unit transmits loop code. It is green continuously when a BERT has no errors, the unit has
a loop, or when the unit is in clear test. It is red during a BERT when the unit receives errors.

ALARM

Both

This red indicator is on continuously when the unit has an active alarm. It flashes when an invalid switch setting has been made.

POWER

Both

This green indicator is on when power is applied to the unit.