6.4.5 Ethernet network configuration by using Telnet

The FD-80 is always available for configuration of the TCP/IP protocol settings, by using
the Telnet network protocol. The default setting of FD-80 service port, for configuration
by using Telnet is:

IP-address 10.0.0.10

Subnet mask 255.0.0.0

Port number 1111

To select the configuration menu, start the Telnet client and use the parameters above,
e.g. under the DOS prompt enter Telnet <IP-address> 1111.

When the connection has been established you will see the following menu in your
Telnet window:

************************
* MINI Com-Server *
************************
1. INFO System
2. SETUP System
3. SETUP Port 0 (Serial)
4. Save Setup

Only one level at a time is shown on the monitor; enter a digit to scroll forward and
press ENTER to move backwards. All settings are activated only after a Save Setup. If
closing the Telnet connection without saving, the FD-80 retains all the settings it had
before opening the configuration menu. The following is an overview of the required
selections to be used by FD-80. The use of these selections are device and mode
dependent, to be described in chapters as follows:

FD-80 P Ethernet slave, Point to point continuously transfer mode

See chapter 6.4.6

FD-80 P Ethernet slave, Point to point addressed mode

See chapter 6.4.7

FD-80 A Ethernet master, addressed mode

See chapter 6.4.8

6.4.5.1 Selections, used by FD-80

SETUP System > Setup TCP/IP
IP-Address

IP-address setting of FD-80.

Subnet Mask

Subnet mask of the subnet in which the FD-80 is located.

Gateway

IP-address of the Gateway, used to get connections from FD-80 to
other subnets.

SETUP Port 0 (Serial) > Port State
Connection State

Online control about the configured TCP/IP mode of the Ethernet
network connection. For access to FD-Tool it must be in mode
FREE, otherwise it has to be device and application dependent.

Clear Port Mode

Revert the port to standard TCP/IP mode, FREE. This setting is
effective without Save Setup after exiting the menu.