Specifications – Westermo GD-01 US User Manual

Page 9

Advertising
background image

9

6696-2230

5. Specifications

GD-01 US

Rated voltage

12 – 36 VDC (reverse polarity protected)

Operating voltage

10.8 – 39.6 VDC

Rated current

350/40 mA @ 12 VDC

online mode/

175/20 mA @ 24 VDC

idle mode

117/17 mA @ 36 VDC

Rated frequency

DC

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24-12)

Power interface

GSM services

Circuit Switched Data

Asynchronous transparent or non-transparent
up to 14.4 kbit/s
MNP2 error correction and V.42 bis data compression

Fax

Fax group 3 (Class 1 and Class 2)

SMS

160 characters text or PDU
Point to point (MT/MO)
Cell broadcast

GPRS

GPRS Class 8, Class B
Coding scheme: CS1 to CS4

Communication and service interface, RS-232

Electrical specification

RS-232

Data rate

300 bit/s – 115.2 kbit/s

Data format

7 or 8 databits, Odd, Even, None, Mark or Space parity

Connection

9-pin D-sub and 5-pin screw terminal

Circuit type

SELV, max 15 m length, shielding not required

Transmission range

15 m

Antenna interface

Frequency

GSM850: 824-849 and 869-894 MHz
GSM1900: 1.850 – 1.910 and 1.930 – 1.990 MHz

Connection

50 ohm impedance SMA female antenna connector

SIM interface

3 volts SIM cards supported

Advertising