background image

Power Inputs

Alarm

V-

V+

SDI-550/541 Industrial Ethernet Switch, conforming IEEE 802.3 and 802.3u standard, supports 5

10/100Base TX (SDI-550) or 4 10/100TX plus one 100FX Ethernet port(SDI-541). SDI-550/541

adopts slim industrial design to save rail space of compact system requirement. In order to survive

under harsh environment, SDI-550/541 chooses industrial-grade aluminum case with IP31 standard

protection.

It provides one relay output to alarm port break events, which is enabled/ disabled by the dip switch.

SDI-550/541 is recommended to be powered by DC24V (18~32V) or AC18V (18~27V) from the

terminal block.

Package Check List

Unpack the box, you will find



SDI-550/541 Switch



Quick Installation Guide

Mounting the Unit



Din-Rail mount: Mount the din-rail clip screwed on the rear

of SDI-550/541 on the DIN rail.

Grounding SDI-550/541 Switch

There is one grounding screw on the bottom side of

SDI-550/541. Connect the frame grounding of switch

to the grounding surface to ensure safety and prevent noise

Wiring the Power Inputs

1. Insert the positive and negative wires into the V+ and V-

contact on the terminal block connector

2. Tighten the wire-clamp screws to prevent the DC wires

from being loosened.

Notes: The recommended working voltage is

DC24V (DC18~ 32 V) or AC18V (18~27V)