Power, Fx sc multi- or single mode (optional), Fx lc multi- or single mode (optional) – Westermo SDW-5xx User Manual

Page 13: Fx st multi mode (optional)

Advertising
background image

13

6644-2214

Power

The SDW-500 series supports redundant power connection.
The positive input are +VA and +VB, the negative input
for both supplies are COM.
The power is drawn from
the input with the highest
voltage.

FX SC Multi- or single mode (optional)

Ethernet FX connection.
1300 nm multi- or singlemode fibre tranceiver with SC-connector.
The dust protection plug shall be mounted when no fibre is connected.

TX

Ethernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover.

CAT 5 cable is recommended.
Unshielded (UTP) or shielded (STP) connector might be used.

8

7

6

5

4

3

2

1

FX LC Multi- or single mode (optional)

Ethernet FX connection.
1300 nm singlemode fibre transceiver with LC-connector.
The dust protection plug shall be mounted when no fibre is connected.

FX ST Multi mode (optional)

Ethernet FX connection.
1300 nm multi mode fibre tranceiver with ST-connector.
The dust protection plugs shall be mounted when no fibre is connected.

12

3

3-pos screw terminal Description Power

1

COM

0 V

2

+VA

A: 9.6 – 57.6 VDC

3

+VB

B: 9.6 – 57.6 VDC

Contact Signal Name Direction Description/Remark

1

TD+

In/Out

Transmitted/Received data

2

TD–

In/Out

Transmitted/Received data

3

RD+

In/Out

Transmitted/Received data

4

5

6

RD–

In/Out

Transmitted/Received data

7

8

Shield

HF-connected