4.2 Isolation between interfaces

Power to all other

1.5 kV RMS @ 50Hz and 60 s duration

FSK-Line to all other

1.5 kV RMS @ 50Hz and 60 s duration

4.3 Environmental

Temperature, operating

5–50°C

Temperature,
storage and transportation

–40 to +85°C

Relative humidity, operating

0 to 95% (non-condensing)

Relative humidity,

0 to 95%

storage and transportation

(condensation allowed outside packaging)

4.4 Mechanical

Dimension (W x H x D)

55 x 100 x 128 mm

Weight

0.5 kg

Mounting

35 mm DIN-rail

Degree of protection

IP 20 (IEC 529)

Advertising