Westermo TD-29P User Manual
Page 7
Advertising
GB.21
6611-2022
4.2 Isolation between interfaces
Power to all other
1.5 kV RMS @ 50Hz and 60 s duration
FSK-Line to all other
1.5 kV RMS @ 50Hz and 60 s duration
4.3 Environmental
Temperature, operating
5–50°C
Temperature,
storage and transportation
–40 to +85°C
Relative humidity, operating
0 to 95% (non-condensing)
Relative humidity,
0 to 95%
storage and transportation
(condensation allowed outside packaging)
4.4 Mechanical
Dimension (W x H x D)
55 x 100 x 128 mm
Weight
0.5 kg
Mounting
35 mm DIN-rail
Degree of protection
IP 20 (IEC 529)
Advertising