6641-2201

Factory Reset

The factory reset option restores the switch to its original factory condition.
The switch will be restored using the following settings.

• IP address 192.168.2.200
• Subnet mask 255.255.255.0
• Gateway 192.168.2.1
• All Ethernet ports are enabled and set to Auto Negotiate
• All applications are disabled
• Password reset to westermo

To perform a Factory Reset follow the procedure below. Read all steps before
starting. If you have any doubts whether the reset is performed or not, do
NOT
unplug the power supply, wait for confirmation according to step 5.

1. Disconnect the power
2. Connect cables between port x1-x6 and port x2-x5.
3. Apply power
4. Wait for approx imately 90 seconds. (Some LED will flash during start up
5. When the Green LED's on all Ethernet ports are constantly on, then remove the

cables connected to port x1-x6 and x2-x5.

6. It is now safe to remove the power and restart the switch.
7. When the switch has started up it will have the default settings.

NOTE! If the power is removed before the factory reset has finished,
the switch may be come unusable.