6641-2201

Phenomena

Test

Description

Test levels

Shock, half sine pulses

IEC 60068-2-27,
Cat. 1 class B
(EN 61373)

Operating

Vertical:

50 m/s

2

Transverse:

50 m/s

2

Longitudinal:

50 m/s

2

30 ms, 3 x 6 shocks

Shock, sawtooth

IEC 60068-2-27,
Cat. 1 class B
(IEEE1478-2001)

Operating

Vertical:

100 m/s

2

Transverse: 100 m/s

2

Longitudinal: 100 m/s

2

11 ms, 3 x 6 shocks

Enclosure

UL 94

Nickel coated zinc

Flammability class V-1

Dimension W x H x D

175 x 100 x 50 mm

Weight

0.8 kg

Degree of protection

IEC 529

Enclosure

IP 65 when all ports are protected/
connected else IP 40

Cooling

Convection

Mounting

Wall mounted