Interface specifications – Westermo DDW-221 User Manual

Page 10

Advertising
background image

10

6642-22102

Interface specifications

Power

Rated voltage

20 to 48 VDC

Operating voltage

16 to 60 VDC

Rated current

300 mA @ 20 VDC
150 mA @ 48 VDC

Rated frequency

DC

Inrush current, I

2

t

3.1 A

2

s

Startup current*

400 mA

Polarity

Reverse polarity protected

Redundant power input

Yes

Isolation to

Ethernet, SHDSL

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

Shielded cable

Not required

* If external power supply is used it must meet specified inrush current.

SHDSL

Electrical specification

ITU-T G.991.2 Annex B

Data rate

192 kbit/s to 5696 kbit/s

Protocol

EFM according to IEEE 802.3-2004

Transmission range

According to ITU-T G.991.2 depending on the line quality

Protection

Overcurrent / overvoltage protection circuit and varistor

Isolation to

Power, Ethernet

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

Shielded cable

Not required

Number of ports

2

Ethernet TX

Electrical specification

IEEE std 802.3 2000 Edition

Data rate

10 Mbit/s, 100 Mbit/s, manual or auto

Duplex

Full or half

Transmission range

100 m / 328 ft

Isolation to

Power, SHDSL

Connection

RJ-45

Shielded cable

Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails**

Number of ports

4 ports marked as 1, 2, 3, 4

** To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m

boundary to the rails and connected to this port.