Connections, Dsl screw connector 1 & 2, Ethernet tx connection (rj-45 connector) 1 – 4 – Westermo DDW-221 User Manual

Page 11: Power connection

Advertising
background image

11

6642-22102

II 3G EEx nA II T4

* Direction relative this unit
** To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary to the rails and connected to this port. The cable shield should be properly connected (360°) to an
earthing point within 1 m from this port. This earthing point should have a low impedance connection to the con-
ductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should
be connected to the earthing system of an installation and may be directly connected to the protective earth.

Connections

DSL screw connector 1 & 2

Position

Direction Description

1

In/Out

2-wire Receive/ Transmit SHDSL

2

In/Out

2-wire Receive/ Transmit SHDSL

Ethernet TX connection
(RJ-45 connector) 1 – 4**

Position

Direction*

Description

1

In/Out

TD+

2

In/Out

TD–

3

In/Out

RD+

4

Not Connected

5

Not Connected

6

In/Out

RD–

7

Not Connected

8

Not Connected

CAT 5 cable is recommended.
Unshielded (UTP) or shielded (STP) connectors
can be used.

LED indicators
(for details see next page)

LED indicators, also

integrated in RJ-45 connector.

(for details see next page)

LED indicators
(for details see next page)

Earth connect

Power connection

Position

Direction*

Description

1

In

+ Voltage A

2

In

+ Voltage B

3

In

Common

4

In

Common

1
2
3
4

Advertising