Factory settings, Description v/y-function, Selection of 2- or 4-wire – Westermo LD-63 HV User Manual

Page 11

Advertising
background image

11

6072-2005

Termination with fail-safe

Transmitted power channel 1

Transmitted power channel 2

The fail-safe function forces the signal state of the
receiver to OFF when the connected
transmitter is in tri-state (transmitter inactive).
The receiver located furthest away shall be terminated.

• • •

• •

• •

• •

• •

10 10 10 11 11 11

9

Supervision table when selecting data bits

7 bits

8 bits

No parity

Parity

1 stop bit

2 stop bits

Number of bits

Low

S3

ON

1 2 3 4

High

S3

ON

1 2 3 4

1
2
3
4
5
6
7
8
9

S2:1-5

S1:1-9

S3:4-1

Low

S2

ON

1 2 3 4 5

High

S2

ON

1 2 3 4 5

Factory settings

S1

ON

1 2 3 4 5 6 7 8 9

S3

ON

1 2 3 4

S2

ON

1 2 3 4 5

Selection of 2- or 4-wire

4-wire

S1

ON

1 2 3 4 5 6 7 8 9

2-wire

S1

ON

1 2 3 4 5 6 7 8 9

Selection of 2-wire RS-485 or 4-wire RS-422.
For RS-232/V.24 S1:1 can be ignored.

Termination (2-wire)

S2

ON

1 2 3 4 5

No termination

S2

ON

1 2 3 4 5

Termination (4-wire)

S2

1 2 3 4 5

ON

V-function

Y-function

LA-01 Y

OR

OR

OR

LA-01 V

OR

F/O

F/O

F/O

F/O

RS-232/V.24 / RS-422/485

RS-232/V.24 / RS-422/485

channel 1

channel 2

channel 1

channel 2

Description V/Y-function

Normally high power is used. Low power is used with fibre
lengths shorter than 100 m.

Normally high power is used. Low power is used with fibre
lengths shorter than 100 m. S3: 2–4 is not used.