6

6643-2230

Type tests and environmental conditions

Environmental phenomena

Basic standard

Description

Test levels

Electrostatic discharge

EN 61000-4-2

Enclosure

Contact: ±6 kV
Air: ±8 kV

Fast transients

EN 61000-4-4

Power port

±2 kV

Ethernet
Status out/Digital in
Serial ports
Enclosure

Surge

EN 61000-4-5

Power port

L-L: ±0.5 kV, 2 Ω, 18 μF
L-E: ±2 kV, 42 Ω, 0.5 μF
L-L: ±1 kV, 42 Ω, 0.5 μF
L-E: ±2 kV, 12 Ω, 9 μF
L-L: ±1 kV, 12 Ω, 9 μF

Ethernet

L-E: ±2 kV, 2Ω, 0.5 μF

Status out/Digital in

L-E: ±2 kV, 42 Ω, 0.5 μF
L-L: ±1 kV, 42 Ω, 0.5 μF

RS-232

L-E: ±2 kV, 2 Ω, 0.5 μF

Power frequency magnetic field

EN 61000-4-8

Enclosure

300 A/m; 0, 16.7, 60 Hz
1000 A/m; 50 Hz

Pulsed magnetic field

EN 61000-4-9

Enclosure

300 A/m

Radiated RF immunity

EN 61000-4-3

Enclosure

20 V/m @ (80 – 2700) MHz
1 kHz sine, 80% AM

Conducted RF immunity

EN 61000-4-6

Power port

10 V, 80% AM, 1 kHz; (0.15 – 80) MHz

Ethernet
Status out/Digital in
Serial ports
Earth port

Radiated RF emission

EN 55022/
FCC Part 15/
DNV 2.4

Enclosure

Class B / DNV bridge

Conducted RF emission

EN 55022/
FCC Part 15/
DNV 2.4

Power port

Class B / DNV bridge

Ethernet

Class B

Compass safe distance

DNV 2.4

Enclosure

Standard compass (5.4°/H deviation) =
15 cm
Steering/standby steering/emergency com-
pass (18°/H deviation) = 10 cm

Dielectric strength

EN 60950-1

Power port to all
other ports

1.5 kVrms, 50 Hz, 1 min

Ethernet ports to all
other ports
RS-232 port to all
other ports