Safety control drawing – Westermo Lynx-x05-S1-EX User Manual

Page 13

Advertising
background image

13

6643-22801

LED Indicators (for details see page 14)

Power connection (for details see page 9 and 13)

I/O connection

(for details see page 10 and 13)

RS-232

Position Signal Direction Description

Input/output values

No.1

DSR

Out

Data Set Ready

U = ±12 V max
I = ±60 mA max
Data rate:

50 bit/s – 115.2 kbit/s

No. 2

DCD

Out

Data Carrier Detect

No. 3

DTR

In

Data Terminal Ready

No. 4

SG

Signal Ground, not chassis

ground

No. 5

RD

Out

Receive Data

No. 6

TD

In

Transmit Data

No. 7

CTS

Out

Clear To Send

No. 8

RTS

In

Request To Send

Safety control drawing

Location of interface ports and LED’s

Ethernet connection TX (4 ports)

Position Signale Direction Description

Input/output values

No.1

TD+

In/Out Transmitted/Received data

Per port:

U = ± 1 V (4μV/s)

I = ± 20 mA
Data rate:

10/100 Mbit/s

No. 2

TD–

In/Out Transmitted/Received data

No. 3

RD+

In/Out Transmitted/Received data

No. 4

Not Connected

No. 5

Not Connected

No. 6

RD–

In/Out Transmitted/Received data

No. 7

Not Connected

No. 8

Not Connected

Shield

Connected to PE

Galvanically isolated via signal transformers and capacitively isolated to

GND/PE through a 2kV 1000pF capacitor.

See user manual for proven transient protection.

USB

Position Direction* / description

Output values

1

Out / VBUS

U

out

= 5 VDC max

I

out

= 500 mA max

2

In/out / D–

3

In/out / D+

4

GND

Shield

PE

Advertising