Safety control drawing, Power connection, I/o connection – Westermo Lynx-x05-S1-EX User Manual

Page 15: Console port

Advertising
background image

15

6643-22801

Power connection

1

2

3

4

4-position

Product

marking

Direction

Description

Input values

No. 1

+DC1

Input

Supply voltage input DC1

U

in

= (19 – 60) VDC

I

in

= 290 mA @ 24 VDC

P

In

= 7 W @ 24 VDC

No. 2

+DC2

Input

Supply voltage input DC2

No. 3

-COM

Input

Common

No. 4

-COM

Input

Common

Lynx supports redundant power connection. The positive inputs are +DC1 and +DC2, the negative input for

both supplies are –COM. Connect the primary voltage (e.g. +24 VDC) to the +DC1 pin and return to one of the

–COM pins on the power input.

I/O connection

1

2

3

4

4-position

Product

marking

Direction

Description

Input / Output values

No. 1

Status +

Output

Alarm relay (status) contact U

in

= 60 VDC max

No. 2

Status –

Output

Alarm relay (status) contact I

in

= 80 mA max

No. 3

Digital in +

Input

Digital in +

U

in

= 60 VDC max

No. 4

Digital in –

Input

Digital in –

I

in

= 2 mA max

The Status output is a potential free, opto-isolated normally closed solid-state relay.

This can be configured to monitor various alarm events within the Lynx unit, see WeOS Management Guide.

An external load in series with an external voltage source is required for proper functionality.

For voltage/current ratings, see Interface Specification section.

The Digital in is an opto-isolated

digital input which can be used to

monitor external events. For volt-

age/current ratings, see Interface

Specification section:

Lynx

External

Load

Status

V

V

Digital In

+

1

2

3

4

Safety control drawing

Console port

Position Direction* / description Input/output values

No.1 In / out / GND

U = 3.3 VDC max

I = 24 mA max

No. 2 Out / Tx
No. 3 In / Rx

* Direction relative to this unit.