Switch settings, Danger! do not open connected unit, Specifications – Westermo MA-21 User Manual

Page 2

Advertising
background image

8

6021-2002

Switch settings

The MA-21 can through different switch settings be adapted to a vareity of running
conditions. To set the switches, open the plastic case by placing and turning a screw-
driver between top and bottom at the rear of the case.

DANGER! DO NOT OPEN CONNECTED UNIT

1 2 3 4 5

V.24/RS-232-C
CONNECTION

LINE

CONNECTION

MAINS

Specifications

Transmission

Asynchronous, full/half duplex or simplex

Interface 1

EIA RS-232-C/CCITT V.24
25-position D-sub female, DCE

Interface 2

20 mA current loop, selectable active or passive

Data rate

Up to 19.2 bit/s

Indicators

Power, RD, TD

Isolation

Galvanic isolation with opto-coupler (data transmission)
and transformer (supply)

Isolation voltage

1500V

Overvoltage protection

Mains: Breakdown voltage 440V at 230V AC
and 220V at 115V AC
Interface 2: Breakdown voltage transmitter
and receiver 37V
Surge capacity 0.6 kW for 1ms

Power supply

Switchable 115/230V +15/ –10% 48–62Hz

Fuse

100mA fast 5x20 mm

Power consumption

Max 5VA at 230V AC

Temperature range

5–50°C, ambient temperature

Humidity

0–95% RH, non-condensing

Dimensions WxHxD

161x53x139 mm

Weight

0.5 kg

Mounting

With rubber pads or screws. Screws: remove
the two "keyholes" on the bottom of the case