10

6049-2001

Connections

Line connection
(5-position screw-terminal)

Direction

Pin

ITU-T V.24

Signal name

no.

Circuit number

I

2

103

TD/Transmitted Data

O

3

104

RD/Received Data

I

4

105

RTS/Request To Send

O

5

106

CTS/Clear To Send

O

6

107

DSR/Data Set Ready

7

102

SG/Signal Ground

O

8

109

DCD/Data Carrier Detect

I

20

108/2

DTR/Data Terminal Ready

I = Input, O = Output MA-49

Terminal connection (DCE)
(RS-232-C/V.24, 25-Position D-sub, female)

Look right for a section of rack RV-01 with
one MA-49 mounted.
Terminal connection to a 25-position D-sub (female) connector on MA-49.
Line connection to a 5-position detachable screw-terminal, which is mounted on the
male connector located at the rear of RV-01.

1

13

25

14

1

2

3

4

5

1 2 3 4 5

Direction

Pin

CCIT V.11

no.

Description

Receiver

1

A’ (R+)

Receiver

2

B’ (R-)

Transmitter

3

A (T+)

Transmitter

4

B (T-)
Shield

The definations R+/R–,T+/T– can be various between
different manufactures.