Specifications ma-67 – Westermo MA-67 User Manual

Page 2

Advertising
background image

8

6067-2001

Specifications MA-67

Transmission

Asynchronous, full/half duplex or simplex

Interface 1

EIA RS-422/RS-485
CCITT V.11, 5-position screw-terminal

Interface 2

ST-connectors, see table of power budget

Surge protection

Interface 1: transient protection,
flashover voltage for receiver and transmitter 7V.
Dissipation capability 0.6 kW for 1 ms.

Insulation

1500V rms isolation withstand voltage between
communication line and mains.

Power supply

+20V DC ±25% (via PS-02)

Fuse

500 mA fast 5x20

Data rate

2.4 kbit/s up to 1,5 Mbit/s

Indicators

Power, TD, RD

Power consumption

Max 80 mA at 20V DC

Temperature range

5-50°C, ambient temperature

Humidity

0-95% RH without condesation

Dimension

100x100 mm

Weight

0.4 kg

Mounting

I 19” rack RV-01, possible to mount
16 MA-67 in a RV-01

Advertising