Specifications md-44, Switch settings md-44, Danger! do not open connected unit – Westermo MD-44 User Manual

Page 2

Advertising
background image

1

2

3

4

5

MD-44 DC

LINE CONNECTION

+

TD RD RTS CTS DCD DTR DSR SG

POWER

R+ R-

V24/RS-232-C

RS-422/RS-485/V11

CONVERTER

T+

T-

PWR

V24/RS-232-C

CONNECTION

1

2

3

4

5

6

7

8

9

;;

yy

S3:1-4

S2:1-9

8

6155-2002

Specifications MD-44

Transmission

Asynchronous, full/half duplex or simplex

Interface 1

EIA RS-232-C/CCITT V.24/V.28
9-position D-sub female, DCE

Interface 2

EIA RS-422/RS-485/CCITT V.11

Data rate

300 bit/s – 38.4 kbit/s

Indicators

Power, RD, DCD, CTS, RTS, TD

Insulation

Galvanic insulation with opto-coupler (data transmission)
and transformer (supply)

Insulation voltage

1500V

Overvoltage protection

Mains: Breakdown voltage 430V at 230V AC
Interface 2: Breakdown voltage
transmitter and receiver 7V
Surge capacity 0.6 kW for 1ms

Power supply

230V +15/–10% 48–62Hz

Fuse

100 mA fast 5x20 mm

Power consumption

Max 22 mA at 230V

Temperature range

5–50°C, ambient temperature

Humidity

0–95% RH, non-condensing

Dimensions

55x100x128 mm (WxHxD)

Weight

0.5 kg AC / 0.25 kg DC

Mounting

On DIN-rail 35 mm

Switch settings MD-44

The MD-44 can through different switch settings be adapted to a variety of running
conditions. To set the switches, open the plastic case with e.g. a screw-driver.

Danger! Do not open connected unit