Connections md-44 ac, Line connection (5-position screw-terminal) – Westermo MD-44 User Manual

Page 4

Advertising
background image

10

6155-2002

Connections MD-44 AC

Line connection
(5-position screw-terminal)

CCITT V.11

Direction

No.

Description

Receiver

1

A’ (R+)

Receiver

2B’ (R–)

Transmitter

3

A

(T+)

Transmitter

4

B

(T–)

5

Shield

Terminal connection (DCE)
(RS-232-C/V.24/V.28, 9-position D-sub, female)

Line connection

Direction 1)

Pin

Screw-

CCITT V.24

Description

no.

terminal

Circuit number

I

3

8

103

TD / Transmitted Data

O

27

104

RD / Received Data

I

7

6

105

RTS / Request to Send

O

8

5

106

CTS / Clear to Send

O

6

2107

DSR / Data Set Ready

5

9 & 1

102SG / Signal Ground

O

1

4

109

DCD / Data Carrier Detect

I

4

3

108/2DTR / Data Terminal Ready

1) I = input

O = output on MD-44

1) If shielded cable is used, connect the shield only at one end to avoid ground currents.

4-wire

MD-44

RS-422/485
equipment

RS-422/485
equipment

Transmitter/
Receiver

Transmitter/
Receiver

Twisted pairs

Twisted pairs

Receiver

Transmitter

Transmitter

Receiver

A’

B’

A

B

A

B

A’

B’

Shield 1)

Shield 1)

A/A’

A/A’

B/B’

B/B’

1

2

3

4

5

3

4

5

MD-44

2-wire

The definations R+/R–,T+/T– can be various between
different manufactures.

Advertising