Switch settings md-63, Selection of turning time/ transmission rate, Selection of 2- or 4-wire – Westermo MD-63 User Manual

Page 4: Selections of bits

Advertising
background image

10

6071-2002

Switch settings MD-63

The MD-63 can through different
switch settings be adapted to a
variety of running conditions. To
set the switches, open the plastic
case by removing the top cover.

S2:1-5

S1:1-9

Selection of Turning time/

Transmission rate

0.4 ms

≤ 2400 bit/s

Turning

time

Transmission

rate

ON

1 2 3 4 5 6 7 8 9

S1

0.2 ms

4 800 bit/s

ON

1 2 3 4 5 6 7 8 9

S1

0.1 ms

9 600 bit/s

ON

1 2 3 4 5 6 7 8 9

S1

75 µs

14 400 bit/s

ON

1 2 3 4 5 6 7 8 9

S1

50 µs

19 200 bit/s

ON

1 2 3 4 5 6 7 8 9

S1

37 µs

28 800 bit/s

ON

1 2 3 4 5 6 7 8 9

S1

25 µs

38 400 bit/s

ON

1 2 3 4 5 6 7 8 9

S1

16 µs

62500 bit/s

ON

1 2 3 4 5 6 7 8 9

S1

11 µs

93 750 bit/s

ON

1 2 3 4 5 6 7 8 9

S1

9 µs

115.2 kbit/s

ON

1 2 3 4 5 6 7 8 9

S1

6 µs

187.5 kbit/s

ON

1 2 3 4 5 6 7 8 9

S1

3 µs

375 kbit/s

ON

1 2 3 4 5 6 7 8 9

S1

2 µs

500 kbit/s

ON

1 2 3 4 5 6 7 8 9

S1

1 µs

1–1.5 Mbit/s

ON

1 2 3 4 5 6 7 8 9

S1

Selection of 2- or 4-wire

S1

4-wire

ON

1 2 3 4 5 6 7 8 9

S1

2-wire

ON

1 2 3 4 5 6 7 8 9

S1: 2-3 not used

Selections of bits

S1

9

ON

1 2 3 4 5 6 7 8 9

S1

10

ON

1 2 3 4 5 6 7 8 9

S1

11

ON

1 2 3 4 5 6 7 8 9

S1

*

ON

1 2 3 4 5 6 7 8 9

*) Use this setting for synchronous protocols.

The transmitter will be active from the start bit
to 10 bit-times after the last high databit
(see example below).
The speed shall be set to

10 times

the required communication speed.

Start bit

1 bit = 52µs

1 bit: 1/1 9200 = 52µs

Data rate 19 200

Transmitter active

Set the speed to 187.5 kbit/s

10x52µs = 520µs

Example 19 200 bit/s

Advertising