SPECIFICATIONS
General
EMC approval
EN55022 (CISPR 22)
- CLASS B
EN 50082-1
I-ETS 300 683
AS 3548
89/336/EEC
Radio approval
EN-300-220
AS 4268.2 AUST
RFS29 NZ
405 - 490 Mhz, 10 - 500 mW
472 Mhz, 100 mW EIRP
458 Mhz, 500 mW EIRP
Housing
160 x 64 x 36mm
IP66
Industrial-grade painted aluminium
I/O & Power Connection
Weatherproof bayonet
connector
Conxall 6282-7SG-522
Suitable for 0.75 mm
2
conductors
Matching female part supplied with
unit
LED indication
Transmit, Operation OK,
Configuration mode,
Reading analogue
Operating Temperature
-40 to 60 degrees C
Power Supply
External Battery supply
11.5 - 15.0 V DC
Overvoltage, reverse power
protected
Internal Battery supply
3 x AA 3.5V Lithium
3 x AA 1.5V alkaline
External battery pack
(optional)
Eveready L91 or equivalent
Duracell MN1500B4 or equiv.
3.5 – 5 VDC