Type tests and environmental conditions – Westermo Viper-008 User Manual

Page 6

Advertising
background image

6

6641-2211

Type tests and environmental conditions

Phenomena

Test

Description

Test levels

ESD

EN 61000-4-2

Enclosure contact 

± 6 kV (crit A)

Enclosure air

± 8 kV (crit A)

RF field AM modulated 

IEC 61000-4-3

Enclosure

20 V/m 80% AM (1 kHz),  
80 – 2500 MHz (crit A)

Fast transient

EN 61000-4-4

Ethernet ports

± 2 kV (crit A)

Power port

± 2 kV (crit A)

Earth port

± 2 kV (crit A)

Surge

EN 61000-4-5

Fault port

± 2 kV line to earth (crit A)

Ethernet ports

± 2 kV line to earth (crit A)

Power port

± 2 kV line to earth, ± 2 kV line to line 
(crit A)

RF conducted

EN 61000-4-6

Ethernet ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz 
(crit A)

Power port

10 V 80% AM (1 kHz), 0.15 – 80 MHz 
(crit A)

Power frequency magnetic 
field 

EN 61000-4-8

Enclosure

1000 A/m 50 Hz 
300 A/m 16.7 Hz, 60 Hz, DC (crit A)

Pulse magnetic field

EN 61000-4-9

Enclosure

300 A/m (crit A)

Voltage dips and interruption  EN 50155

DC power ports

10 ms, interruption (crit A)
100 ms +- 40 % above/below  
rated voltage (crit A)

Radiated emission 

EN 55022

Enclosure

Class B

FCC part 15

Class B

Conducted emission

EN 55022

DC power port & 
Ethernet ports

Class B

FCC part 15

DC power port

Class B

Dielectric strength

EN 50155

Ethernet ports to other 
isolated ports

707 VDC 1 min

Power & Fault port to 
other isolated ports

2121 VDC 1 min

Temperature

Operating

–40 to +70ºC

Storage & Transport

–40 to +70ºC

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2000 m / 70 kPa

Reliability prediction (MTBF)

MIL-C217F2

Operating

Ground Benign:  
150 years @ 20 ºC
147 years @ 40 ºC
135 years @ 60 ºC
Ground Mobile:  
9,87 years @ 20 ºC
9,85 years @ 40 ºC
9,79 years @ 60 ºC
Ground Fix: 
28,54 years @ 20 ºC
28,43 years @ 40 ºC
27,95 years @ 60 ºC

Service life

Operating

10 year

Vibration, random simulated 
long life 

IEC 60068-2-64,
Cat. 1 class B
(EN 61373)

Not Operating

Vertical: 

7.9 m/s

2

Transverse:  7.9 m/s

2

Longitudinal:  7.9 m/s

2

3 x 5 h

Vibration, random functional

IEC 60068-2-64,
Cat. 1 class B
(EN 61373)

Operating

Vertical: 

1.0 m/s

2

Transverse: 

1.0 m/s

2

Longitudinal:  1.0 m/s

2

3 x 10 min