Interface specifications – Westermo Viper-008 User Manual

Page 9

Advertising
background image

9

6641-2211

Interface specifications

Power and fault relay port PWR  
Rated voltage

24 to 110 VDC

Operating voltage

24 to 110 VDC ±40%

Rated current

30 mA @ 110 VDC
90 mA @ 24 VDC

Rated frequency

DC 

Inrush current, I

2

t

Max 0.02 A

2

s  @ 24 – 110 VDC

Polarity

Reverse polarity protected

Redundant power input

No

Isolation to

Connections X1 – X8 and to ground, 1500 VAC.
Fault relay belongs to the same isolation group as the power 
supply lines (fault relay signals are also contained within 
PWR).

Connection

4 pin male M12 connector with A-code

Connector size

M12, recommended cable area 0.5 mm

2

 recommended  

(minimum 0.25 mm

2

), cable dimensions depend on choice of 

M12 connector

Shielded cable

Not required, twisted pair is recommended

Fault relay resistance

< 10 Ω

Operating voltage

Up to 110 VDC

M12 A-Coded 

Power 

Connector

Position

Direction

Description

1

U+

Positive supply voltage

2

Out

Alarm relay (status) +

3

0 V

Negative supply voltage

4

Out

Alarm relay (status) –

Housing

Shield

Chassis of product (ground)