EMI High Wall Evaporator WLC/WLH User Manual

Specifica tion s and p erformance, Wlc/wlh high wall evaporator

Advertising
background image

Web: http://www.enviromaster.com

Enviromaster International LLC

1

Specifica

tion

S

and

p

erformance

ProduCt dEsCrIPtIon

The AmericaSeries WLC/WLH offers a contemporary
design, ductless type evaporator combining attractive

appearance in any decor and high efficiency condition-
ing for small to medium size commercial or residential
spaces. The WLC/WLH is equipped with unit mounted
infrared compatible controls which also supports 24V
remote wall thermostat operation. Optional hand held
remote is available.

Heat Pump models provide up to a nominal 24,000 Btuh
of cooling and heating. Electric heat options are available
for up to 5KW of supplemental heat.

This American-made evaporator offers ease of instal-
lation, operation, and service. It can be matched with
EMI’s S1C/S1H 09-24 and S1C 30-36 Btuh Single-Zone
Condensing Units, the S2C side discharge Multi-Zone
Condensing Unit, or the T2C, T3C, and T4C top discharge
Multi-Zone Condensing Units.

Unit Mounted Control:

• Large LCD Backlit Display

• Single unit mounted control package, configurable

to either unit mount or remote wall thermostat
operation, reducing model number or SKU’s
required.

• Universal control can be used in cooling only,

cooling with electric heat, heat pump, or heat pump
with second stage electric heat applications.

Straight cool/heat pump*

Nominal Circuit Capacities: WLH 9,000, 12,000,

18,000, 24,000 Btuh and WLC (only) 30,000 & 36,000 Btuh

* Heat Pump only available for 9,000-24,000 Btuh units.

Wlc/Wlh

high Wall eVaporator

• Operational range set point temperature

adjustable between 55°F and 90°F in one-degree
increments.

• Infra red compatible control allows use of optional

IR hand held controller

notE: Unit mounted controls are fully functional
without the handheld remote.

• Operation modes include Heat, Cool, Dry, Fan and

Auto Change-over.

• Fan Operation – Auto/On. High or Low speed fan

• Fan Purge – Fan remains on for 60 seconds after

Heat/Cool call is dropped for improved efficiency
(Auto mode only)

• Room air sampling: Selectable time intervals

ensures the fan will cycle on periodically, in Auto
Fan Mode.

Benefit: Helps to eliminate room temperature

stratification.

• Selectable Fahrenheit (°F) or Centigrade (°C)

temperature scale.

• Dry mode – Operates cooling and electric heat

simultaneously to remove humidity. Optional
electric heat must be selected.

• Anti-Short Cycle Compressor Protection.

• Minimum on time for heating and cooling.

Benefit: Helps eliminate room temperature drop

and system short cycling.

• Freeze Protection – Prevents evaporator freeze up.

• Test operation – Allows ease of testing after

installation (all timers are eliminated).

• Non-volatile back-up memory

Benefit: Control settings are maintained for an

indefinite period during a power outage. When power
is restored the equipment will resume operation after
a three-minute compressor time delay.

• 7-day programmable with copy feature.

• Filter change indicator: A timer feature that

indicates the filter should be changed according to
the selected time.

• Motorized supply louver with optional sweep or

six stationary settings.

• Modular design – reduces parts required for control

stAndArd FEAturEs

P/N 240005842, Rev. A [05/08]

Advertising