Made in rome, new York, usA

the ductless split system of Choice

2

A

B

C

D

E

5 ¼”

1 ½”

2”

4 ⅜”

package. Deco panel, relay board, ribbon cables and
microprocessor all combined into one package.

Integral condensate pump safety-switch connection

where-by the microprocessor monitors the condensate
pump safety switch and displays an error code when
a fault occurs. (Applys only with optional condensate
pump)

CEC (California Energy Commission) compliant

• Condensate drain pan over flow protection

Cabinet Features:

• Durable ABS plastic cabinet with a galvanized steel

sub-chassis.

• Easily accessible, washable, reusable, nylon mesh filter.

• Horizontal discharge louver, constructed of high

temperature ABS plastic, that can be set to oscillate,
or can be parked in various pre-set positions.

• Manually adjustable vertical discharge fins.

• Easy access to pipe chase area from cabinet bottom.

Benefit: Allows piping connections and condensate
pump installation with the unit mounted on the wall.

• Easily removable end-cap for access to control area

for installation and service.

• Condensate drain pan constructed of galvanized steel

(G90U), with anti-corrosion coating.

• Modular snap-in, 7-day programmable control with

large backlit LCD display, a “Change filter” display
feature and selectable Fahrenheit (Fº), or Centigrade
(Cº) temperature scale.

• Operational range between 55ºF to 90ºF, adjustable

in one-degree increments.

oPtIonAL EquIPMEnt

• Condensate pump (field installed)

• 24V remote wall thermostat

• Electric heat with automatic reset high temperature

cutout and redundant high temperature fuse link
(when heat option is selected)

• Hand held infrared controller.

InstALLEr suPPLIEd ItEMs

• Low voltage wiring

• Power wiring

• Mounting screws and fasteners

• Condensate piping

• Refrigerant piping (if not supplied)

• Refrigerant (for interconnect charge)

stAndArd FEAturEs

Continued

WLC/WLH FEAturEs And oPtIonAL EquIPMEnt

notE:

Due to ongoing development programs, design and specifications may change without notice.

WLC/WLH dIMEnsIons And sPECIFICAtIons

notE:

Due to ongoing development programs, design and specifications may change without notice.

WLC/WLH PHYsICAL dIMEnsIons

Model

“A”

depth

“B”

Height

“C”

Length

“d”

Mounting

Bracket

Clearance

“E”

tubing

Access

Clearance

WLH09

9 ⅞”

15 ¼”

38 ½”

24”

26 ½”

WLH12

9 ⅞”

15 ¼”

38 ½”

24”

26 ½”

WLH24

9 ⅞”

15 ¼”

48 ½”

34”

36 ½”

WLC30

9 ⅞”

15 ¼”

58 ½”

44”

46 ½”

WLC36

9 ⅞”

15 ¼”

58 ½”

44”

46 ½”

WLC/WLH

sHIPPIng WEIgHt

Model

Lbs.

WLH09/12

70

WLH18/24

108

WLC30/36

TBD

Advertising