Chapter 5: maintenance, 3 shutting down the collector – AEC Self Cleaning Continuous Filters User Manual

Page 31

Advertising
background image

Self Cleaning Continuous Filter Chapter 4: Operation

30

Figure 16: Collector Process Air Flow

4-3 Shutting Down the Collector

Dust Control and Pneumatic Conveying Systems

1. Turn off the main fan.

2. Wait five to ten minutes and turn off the timer and discharge (auxiliary) equipment.

3. Turn off the compressed air.

Process System

1. Dryers and the system to the collector discharge should be run until empty and heat

maintained at a reduced rate until the collector metal surfaces and filter bags are dry.

2. Perform steps 1 through 3 listed above in the Dust Control and Pneumatic Conveying

System section.

Advertising