Maintenance / diagnostics / rePairs

- Clean only with a soft wet cloth.
- DO NOT use detergents or aggressive products.
- DO NOT aim water jets directly at the navigator.

5.1 Troubleshooting

ProBleM

cause

solution

The display does not switch on

No power supply

• Check power supply connection.

No signal enabling treatment to
SKIPPER LT

Power cable improperly
connected

• Check green lead connection to power
cable

(par. 4.7).

Improper set-up

• Check set-up

(par. 4.7).

Display shows message

The GPS receiver doesn't give

valid data

Wrong GPS antenna cable con-
nection

• Check connection with GPS antenna
(par. 4.7).

Satellite connection in progress

• Wait for connection to be established.

Display shows message

Differential correction not

available

DGPS signal not available in the
work area

• Disable DGPS.

DGPS connection in progress

• Wait for connection to be established.

Tab. 1

6

technical data

Description

SKIPPER LT

Display

LCD 4", 65000 colors, 420 cd/m

2

Power supply

9 - 15 Vdc

Working temperature

0 °C ÷ 45 °C

+32 °F ÷ +113 °F

Storage temperature

-20 °C ÷ 60 °C

-4 °F ÷ +140 °F

Weight

550 g

1 USB 1.1 port

HOST

Treatment input

Active high (+12 Vdc)