11 rev counter (rpm sensor), 12 foam marker, 11 rev counter (rpm sensor) 12.12 foam marker – ARAG GCS 3200 User Manual

Page 23: Advanced setup

Advertising
background image

23

ADVANCED SETUP

12.11

Rev counter (RPM Sensor)

Fig. 44

Fig. 45

Set the data of the RPM sensor (if installed in the system):

Constant

: indicate the constant of the installed RPM sensor.

Minimum speed alarm

Maximum speed alarm

The speed alarms (minimum or maximum) activate when the measured RPM
exceed the set limits.
The control is active only when the spraying is active (main switch
ON).

Increase rotation speed!

Reduce rotation speed!

Speed alarms

If the RPM sensor is

Disabled

, items

Min. speed alarm

and

Max.

speed alarm

(Fig. 45) are no longer visible on the display.

12.12

Foam Marker

Fig. 46

Foam marker
RIGHT

Foam marker
LEFT

Fig. 47

Set foam marker operating mode:

Manual

Foam marker is operated from the dedicated keys (Fig. 47).

Semi-autom.

Main switch ON --> foam marker ON
Main switch OFF --> foam marker OFF

Automatic

Main switch ON --> foam marker ON
Main switch OFF --> foam marker OFF
Whenever the foam marker is ON, the active side changes automatically.