4.2

Adjustment of maximum operating pressure (only applicable for units with proportional

valve)

Should either of the following be noted during operation:
• pressure above the maximum limit for the system and safety valve;
• abnormal leaks of liquid;
stop work, switch the pump off and check that the installation and preliminary procedures
have been completed correctly.

1 Start pump operation.

2

Set the relevant switch on the control
device to 'ON' to open the main valve:
this will let fluid in through the system.

3 Gradually increase the number of revs of the pump until the maximum operating level is reached.

4

Push up the relevant switch on the control device to fully close the
proportional valve.

5

Close all the compensation cocks by turning their knobs clockwise.

6

Adjust the maximum pressure valve
by turning its knob clockwise until the
pressure of the valve is about 20%
above the unit’s maximum operating
pressure.