Configuration procedure – H3C Technologies H3C S10500 Series Switches User Manual
Page 193

178
Figure 53 Network diagram for PIM-DM configuration
Ethern
et
E
th
e
rnet
E
thernet
N1
N2
Vl
an
-in
t102
Vlan-
int1
02
Vlan-
in
t10
3
Vl
an-
int103
Device
Interface
IP address
Device
Interface
IP address
Switch A
Vlan-int100
10.110.1.1/24
Switch D
Vlan-int300
10.110.5.1/24
Vlan-int103
192.168.1.1/24
Vlan-int103
192.168.1.2/24
Switch B
Vlan-int200
10.110.2.1/24
Vlan-int101
192.168.2.2/24
Vlan-int101
192.168.2.1/24
Vlan-int102
192.168.3.2/24
Switch C
Vlan-int200
10.110.2.2/24
Vlan-int102
192.168.3.1/24
Configuration procedure
1.
Configure IP addresses and unicast routing.
Configure the IP address and subnet mask for each interface as per
. (Details not shown)
Configure OSPF on the switches in the PIM-DM domain to ensure network-layer reachability among them.
(Details not shown)
2.
Enable IP multicast routing, and enable PIM-DM and IGMP.
# Enable IP multicast routing on Switch A, enable PIM-DM on each interface, and enable IGMP on
VLAN-interface 100, which connects Switch A to the stub network.
<SwitchA> system-view
[SwitchA] multicast routing-enable
[SwitchA] interface vlan-interface 100
[SwitchA-Vlan-interface100] igmp enable
[SwitchA-Vlan-interface100] pim dm
[SwitchA-Vlan-interface100] quit
[SwitchA] interface vlan-interface 103
[SwitchA-Vlan-interface103] pim dm
[SwitchA-Vlan-interface103] quit