H3C Technologies H3C MSR 3600 User Manual
Page 31

23
IMPORTANT:
The resistance reading should be smaller than 5 ohms between the chassis and the ground.
Grounding the router through the grounding terminal on the
rack
IMPORTANT:
Make sure the rack is correctly grounded before grounding the router.
To connect the grounding cable:
1.
Remove the grounding screw from the grounding hole on the rear panel of the chassis.
2.
Use the grounding screw to attach the ring terminal of the grounding cable to the chassis.
See
3.
Remove the hex nut on the grounding post of the grounding strip on the rack.
4.
Use needle-nose pliers to bend a hook at the other end of the grounding cable, attach it to the
grounding post, and secure it with the hex nut. See
Figure 27 Connecting the grounding cable to the router