H3C Technologies H3C MSR 2600 User Manual

Page 13

Advertising
background image

6

Item Requirements

Result

Temperature

0°C to 45°C (32°F to 113°F).

Relative humidity

5% to 90% (noncondensing).

Cleanness

•

Dust concentration ≤ 3 × 10

4

particles/m

3

.

•

No visible dust on desk within three days.

ESD prevention

•

The equipment and floor are correctly grounded.

•

The equipment room is dust-proof.

•

The humidity and temperature are at acceptable

levels.

•

Wear an ESD wrist strap and uniform when

touching a circuit board.

•

Place the removed interface module on an

antistatic workbench, with the face upward, or put

it into an antistatic bag.

•

Touch only the edges, instead of electronic

components when observing or moving a removed

interface module.

EMI prevention

•

Take effective measures to protect the power

system from the power grid system.

•

Separate the protection ground of the router from

the grounding device or lightning protection

grounding device as far as possible.

•

Keep the router far away from radio stations, radar

and high-frequency devices working in high

current.

•

Use electromagnetic shielding when necessary.

Lightning
protection

•

The grounding cable of the chassis is correctly

grounded.

•

The grounding terminal of the AC power

receptacle is correctly grounded.

•

A port lightning arrester is installed. (Optional.)

•

A power lightning arrester is installed. (Optional.)

•

A signal lightning arrester is installed at the input

end of an external signal cable. (Optional.)

Electricity safety

•

Equip an uninterrupted power supply (UPS).

•

In case of emergency during operation, switch off

the external power switch.

Workbench

•

The workbench is stable enough.

•

The workbench is correctly grounded.

Rack-mounting
requirements

•

The rack is equipped with a good ventilation

system.

•

The rack is sturdy enough to support the weight of

the router and installation accessories.

•

The size of the rack is appropriate for the router.

•

The front and rear of the rack are at least 0.8 m

(2.62 ft) away from walls or other devices.

Safety
precautions

•

The router is far away from any moist area and heat source.

•

The emergency power switch in the equipment room is located.

Advertising