9

ESD prevention

CAUTION:
•

Check the resistance of the ESD-preventive wrist strap for safety. The resistance reading should be in
the range of 1 to 10 megohm (Mohm) between human body and the ground.

•

The UTM device does not provide any ESD-preventive wrist strap. Prepare it yourself.

To prevent electrostatic discharge (ESD), follow these guidelines:

•

Make sure the UTM device and rack are properly grounded.

•

An anti-static floor is installed and properly grounded.

•

Maintain the humidity and temperature at a proper level in the equipment room. For more
information, see "

Temperature and humidity

."

•

Always wear an ESD-preventive wrist strap and ESD-preventive cloth when touching an interface
module or transceiver module.

•

Place the removed CF card or interface module on an antistatic workbench, with the face upward,
or put it into an antistatic bag.

•

Touch only the edges, instead of electronic components when observing or moving a removed CF
card or interface module.

Make sure the rack is properly grounded before you wear an ESD-preventive wrist strap.
To use the ESD-preventive wrist strap:

1.

Wear the wrist strap on your wrist.

2.

Lock the wrist strap tight around your wrist to keep good contact with the skin.

3.

Insert the ESD-preventive plug into the ESD-preventive socket in the chassis.

4.

Attach the alligator to the chassis.

Advertising