Configuration
Local On-board Configuration
The module parameters can be configured locally using the on-board
rotary switch, the paddle switch and LEDs as described in
. The CONF LED indicates status of the configuration process.
Use the following controls illustrated in
to configure the module
locally:
•
Function (rotary) switch selects a desired configuration parameter from
two banks of 16 positions each (0 through 9, A through F), although not
all positions are used.
•
SW1 paddle switch initiates a configuration parameter selection.
•
CONF (configuring) LED when on, indicates the module is initializing
or processing configuration information.
Figure 8. Module Configuration Switches and LEDs
SW1 – Function Rotary Switch
SW2 – Selection Paddle Switch
CONF (yellow)
8037_06r1
2nd – LED on for 2nd Bank Selections