Service – Grass Valley 8960DEC User Manual

Page 44

Advertising
background image

44

8960DEC—Instruction Manual

Service

Service

The 8960DEC modules make extensive use of surface-mount technology
and programmed parts to achieve compact size and adherence to
demanding technical specifications. Circuit modules should not be ser-
viced in the field unless directed otherwise by Customer Service.

If your module is not operating correctly, proceed as follows:

•

Check frame and module power and signal present LEDs.

•

Verify power at the voltage testpoints (see

Figure 21

) and check Fuse F1

if no voltage is detected.

•

Check for presence and quality of input signals.

•

Verify that source equipment is operating correctly.

•

Check cable connections.

•

Check output connections for correct I/O mapping (correct input con-
nector is used for the corresponding channel output).

Refer to

Figure 6

for the location of PWR LED and

Table 2 on page 17

for

proper LED indications.

If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.

Refer to the 8960DEC at the front of this document for the Grass Valley Cus-
tomer Service Information number.

Figure 21. Fuse and Voltage Testpoint Locations

JP13

pin 1, +5 V

pin 3, -5 V

JP1

JP13

Voltage Testpoints

Fuse: 2 A FAST

125 V

F1

Ground Testpoint

Advertising